Lithonia Lighting LQM S W 3 G 120/277 EL N M6 Thermoplastic LED Exit Sign With Green Letters and Nickel Cadium Battery
PART# LQM S W 3 G 120/277 EL N M6
Web Price
Please call 1-800-983-1315 for the lowest available price- Lumen:7.625"lm
-
-
Type of Area | Home & Architectural, Large Retail & Open Areas, Office & Small Retail, Stairwell |
---|---|
Certifications | NEC, NEMA, OSHA, UL Listed |
Dimmable | No |
Lamp Life: | 100,000 Hours |
Length | 11.75" x 2.00" x 7.625" |
Width | 11.75" |
Height | 2.00" |
Lumen Output: | 7.625" |
Manufacturer | Lithonia Lighting |
Product Warranty | 5 Year |
Part Number | LQM S W 3 G 120/277 EL N M6 |
Technology | LED |
Voltage | Multivolt 120V-277V |
Weight Each | 2.60 lbs |
Bulbs Included? | Yes |
ShineRetrofits Input:
Lithonia's Lighting's LQM Thermoplastic Exit sign is impact-resistant, scratch resistant, and corrosion proof and features a uni-body housing that snaps together easily for installation. Includes Ni-cad battery back up providing up to 90 minutes of emergency lighting and extremely bright LEDs that are visible up to 100 feet away meeting UL924 standards. Durable and designed to last.
Intended Use:
Ideal for applications requiring attractive, quick-installation exit signs and low energy consumption.
Construction:
Engineering-grade thermoplastic housing is impact-resistant, scratch-resistant, and corrosion-proof. UL94V-0 flame rating. UV-stable resin resists discoloration from natural and man-made light sources.
Rugged unibody housing snaps together with no additional mechanical fasteners. Faceplate and back cover are interchangeable on housing. Positive snap-fit tabs hold faceplate securely, yet easily removable for lamp compartment access.
Universal directional Chevron inserts are easily removed and reinserted. Uniform illumination without
shadows or hot spots. Reinforced, impact-resistant color panels. Letters 6” high with 3/4” stroke, with 100 ft. viewing distance rating, based upon UL924 standards.
U.S. Patent No. 5,526,251; 5,611,163; 5,739,639; 5,954,423; 5,988,825; 6,152,581; D383,501 ;
D495,751 and 6,502,044. Other patents pending.
Optics:
LEDs mounted on printed circuit boards. Low energy consumption – less than one watt. LED
lamp operates in normal (AC input) and emergency (DC input) modes.
The typical life of the exit LED lamp is 10 years.
Electrical:
Dual voltage input capability (120/277V).
Low-voltage disconnect prevents excessively deep discharge that can permanently damage battery. Conveniently
located test switch and LED provide visual and manual means of monitoring system.
Constant-current series charger minimizes energy consumption and provides low operating costs. Printed
circuit boards are 100% quality tested during manufacturing. Current-limiting charger circuitry protects
printed circuit boards from shorts.
AC/LV reset (line latch) allows battery connection before AC power is applied and aids in preventing battery
damage from deep discharge.
Crystal oscillator timing system with watchdog protection for precision accuracy.
Brownout protection is automatically switched to emergency mode when supply voltage drops below
80% of nominal.
Battery: Sealed, maintenance-free nickel-cadmium battery delivers 90-minutes capacity to emergency lamps.
Two-state constant-current charge maximizes battery life and automatically recharges after battery discharge.
Diagnostics: Single-point microcomputer control for all electronic features.
Single multi-chromatic LED indicator to display two-state charging, test activation and three-state diagnostic
status.
Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection.
Self-diagnostic testing for five minutes every 30 days and 30 minutes every six months.
Diagnostic evaluation of LED light source, AC to DC transfer, charging and battery condition. Continuously
monitors AC functionality.
Installation:
Universal (top-, end-, or back-) mounting. Easily removed mounting knockouts. J-box
pattern on back panel. Housing snaps to canopy with four positive-locking tabs. Cam-locking pin tightly
secures housing to canopy.
Ships standard with additional face plate.
Listings:
UL damp location listed 50°-104°F (10°-40°C) standard. NOM Certified (see options). Meets
UL924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. NEMA Premium certified.
Meets all applicable FCC requirements.
ShineRetrofits Input:
Lithonia's Lighting's LQM Thermoplastic Exit sign is impact-resistant, scratch resistant, and corrosion proof and features a uni-body housing that snaps together easily for installation. Includes Ni-cad battery back up providing up to 90 minutes of emergency lighting and extremely bright LEDs that are visible up to 100 feet away meeting UL924 standards. Durable and designed to last.
Intended Use:
Ideal for applications requiring attractive, quick-installation exit signs and low energy consumption.
Construction:
Engineering-grade thermoplastic housing is impact-resistant, scratch-resistant, and corrosion-proof. UL94V-0 flame rating. UV-stable resin resists discoloration from natural and man-made light sources.
Rugged unibody housing snaps together with no additional mechanical fasteners. Faceplate and back cover are interchangeable on housing. Positive snap-fit tabs hold faceplate securely, yet easily removable for lamp compartment access.
Universal directional Chevron inserts are easily removed and reinserted. Uniform illumination without
shadows or hot spots. Reinforced, impact-resistant color panels. Letters 6” high with 3/4” stroke, with 100 ft. viewing distance rating, based upon UL924 standards.
U.S. Patent No. 5,526,251; 5,611,163; 5,739,639; 5,954,423; 5,988,825; 6,152,581; D383,501 ;
D495,751 and 6,502,044. Other patents pending.
Optics:
LEDs mounted on printed circuit boards. Low energy consumption – less than one watt. LED
lamp operates in normal (AC input) and emergency (DC input) modes.
The typical life of the exit LED lamp is 10 years.
Electrical:
Dual voltage input capability (120/277V).
Low-voltage disconnect prevents excessively deep discharge that can permanently damage battery. Conveniently
located test switch and LED provide visual and manual means of monitoring system.
Constant-current series charger minimizes energy consumption and provides low operating costs. Printed
circuit boards are 100% quality tested during manufacturing. Current-limiting charger circuitry protects
printed circuit boards from shorts.
AC/LV reset (line latch) allows battery connection before AC power is applied and aids in preventing battery
damage from deep discharge.
Crystal oscillator timing system with watchdog protection for precision accuracy.
Brownout protection is automatically switched to emergency mode when supply voltage drops below
80% of nominal.
Battery: Sealed, maintenance-free nickel-cadmium battery delivers 90-minutes capacity to emergency lamps.
Two-state constant-current charge maximizes battery life and automatically recharges after battery discharge.
Diagnostics: Single-point microcomputer control for all electronic features.
Single multi-chromatic LED indicator to display two-state charging, test activation and three-state diagnostic
status.
Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection.
Self-diagnostic testing for five minutes every 30 days and 30 minutes every six months.
Diagnostic evaluation of LED light source, AC to DC transfer, charging and battery condition. Continuously
monitors AC functionality.
Installation:
Universal (top-, end-, or back-) mounting. Easily removed mounting knockouts. J-box
pattern on back panel. Housing snaps to canopy with four positive-locking tabs. Cam-locking pin tightly
secures housing to canopy.
Ships standard with additional face plate.
Listings:
UL damp location listed 50°-104°F (10°-40°C) standard. NOM Certified (see options). Meets
UL924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. NEMA Premium certified.
Meets all applicable FCC requirements.