Howard Lighting EPH2/32IS/MV/MC/HE 2 Lamp T8 Electronic Ballast F32T8 120-277V High Power Micro Case
PART# EPH2/32IS/MV/MC/HE
Web Price
Please call 1-800-983-1315 for the lowest available price-
Wattage:64 Watt
-
UPC | 799385-04665 |
---|---|
Certifications | ANSI, ROHS, UL Listed |
Dimmable | No |
Number of Lamps | 2 Lamp |
Dimensions | 9.5" x 1.3" x 1.0" |
Length | 9.5" |
Width | 1.3" |
Height | 1" |
Manufacturer | Howard Lighting |
Product Warranty | 5 Year |
Part Number | EPH2/32IS/MV/MC/HE |
Minimum Start Temperature | 0 Deg F |
Technology | T8 Fluorescent |
Voltage | Multivolt 120V-277V |
Wattage | 64 Watt |
Power Factor | 98% |
ShineRetrofits Input:
The Howard Lighting EPH2/32IS/MV/MC/HE is a high-power electronic fluorescent ballast that operates 2 lamps. The ballast uses a parallel lamp operation with an instant start, and a minimum lamp starting temperature for the primary lamp of 0°F. Additionally, the ballast is UL certified and comes with a five-year warranty.
Ballast Specifications
• Ballast shall have a five-year warranty
• Ballast shall be UL certified
• Ballast shall be sound rated Class A
• Ballast shall be Class P Type 1 Outdoor
• Ballast shall have a Lamp Current Crest Factor of <1.7
• Ballast shall withstand line transients as specified in ANSI C62.41-1991
• Ballast shall comply with the limits of FCC Part 18 Class A
• Ballast shall have a lamp operating frequency greater than 40kHz
• Ballast shall have a 0F minimum lamp starting temperature for primary lamp
• Ballast shall be Instant Start
• Ballast shall be Parallel Lamp Operation
• Ballast shall have minimum Power Factor of 98% for primary Lamp operation
• Ballast shall operate within +/- 10% of the ballast specified line voltage at 60 Hz
• Ballast shall have a maximum case hot spot temperature of 70 Celsius
ShineRetrofits Input:
The Howard Lighting EPH2/32IS/MV/MC/HE is a high-power electronic fluorescent ballast that operates 2 lamps. The ballast uses a parallel lamp operation with an instant start, and a minimum lamp starting temperature for the primary lamp of 0°F. Additionally, the ballast is UL certified and comes with a five-year warranty.
Ballast Specifications
• Ballast shall have a five-year warranty
• Ballast shall be UL certified
• Ballast shall be sound rated Class A
• Ballast shall be Class P Type 1 Outdoor
• Ballast shall have a Lamp Current Crest Factor of <1.7
• Ballast shall withstand line transients as specified in ANSI C62.41-1991
• Ballast shall comply with the limits of FCC Part 18 Class A
• Ballast shall have a lamp operating frequency greater than 40kHz
• Ballast shall have a 0F minimum lamp starting temperature for primary lamp
• Ballast shall be Instant Start
• Ballast shall be Parallel Lamp Operation
• Ballast shall have minimum Power Factor of 98% for primary Lamp operation
• Ballast shall operate within +/- 10% of the ballast specified line voltage at 60 Hz
• Ballast shall have a maximum case hot spot temperature of 70 Celsius