Howard Lighting EP4/32PPRS/MV/SC/HE 4 Lamp F32T8 Parallel Program Rapid Start High Efficiency Electronic Ballast 120-277V
PART# EP4/32PPRS/MV/SC/HE
Web Price
Please call 1-800-983-1315 for the lowest available priceUPC | 799385-05295 |
---|---|
Ballast Factor | Normal .87-.88 |
Certifications | ANSI, ROHS, UL Listed |
Dimmable | No |
Number of Lamps | 4 Lamp |
Dimensions | 9.5"L x 1.18"H x 1.65"W |
Length | 9.5" |
Width | 1.65" |
Height | 1.18" |
Manufacturer | Howard Lighting |
Product Warranty | 5 Year |
Part Number | EP4/32PPRS/MV/SC/HE |
Minimum Start Temperature | 0 Deg F |
Technology | T8 Fluorescent |
Voltage | Multivolt 120V-277V |
Total Harmonic Distortion [THD] | <10% |
Power Factor | 0.97 |
ShineRetrofits Input:
The Howard Lighting EP4/32PPRS/MV/SC/HE electronic fluorescent ballast operates four lamps with standard ballast factor. It is a high efficiency ballast designed to conserve energy and uses parallel program rapid start. The ballast has a 0°F minimum start temperature for the primary lamp. It is UL Listed with a five year warranty.
Ballast Specifications
*Ballast shall have a five-year warranty
*Ballast shall be UL certified
*Ballast shall be sound rated Class A
*Ballast shall be Class P Type 1 Outdoor
*Ballast shall have a Lamp Current Crest Factor of <1.7
*Ballast shall withstand line transients as specified in ANSI C62.41
*Ballast shall meet with ANSI C82.11 performance standard
*Ballast shall meet with ANSI C82.77 harmonic standard
*Ballast shall comply with the limits of FCC Part 18 Class A
*Ballast shall have a lamp operating frequency greater than 40kHz
*Ballast shall have a 0°F minimum lamp starting temperature for primary lamp
*Ballast shall be Instant Start
*Ballast shall be Parallel Lamp Operation
*Ballast shall have minimum Power Factor of 97% for primary Lamp operation
*Ballast shall operate within +/- 10% of the ballast specified line voltage at 60 Hz